D1030
Tie Down Engineering
255 Villanova Drive SW
Atlanta, Georgia 30336
(404) 344-0000 • Fax (404) 349-0401
www.tiedown.com
Example of a Triple Section 32' x 72' Home
WIND ZONE III for Triple Section Homes
Using Vector Dynamics Foundation Systems
Soil Classifications: 2, 3, 4A & 4B
Soil Bearing Capacity: 1,000 PSF Minimum
Anchors Required*: 30”with2-4”helixanchors(#59095)with1-1/4” vertical ties
(*Marriagewall and sheer wall anchors may be required by home manufacturer.)
Home Length Vector Systems Anchors Required Longitudinal
Required Per Side System
1
(LSD)
0 to 48' 3 + 2 on Tag 5 3(6Struts)
49' to 60' 4 + 2 on Tag 6 3(6Struts)
61' to 72' 5 + 2 on Tag 7 3(6Struts)
73' to 84' 6 + 2 on Tag 8 3(6Struts)
85’ to 90’ 7 + 2 on Tag 9 3(6Struts)
NOTES:
Vector Systems should be spaced as symmetrical as possible along the length of the home. Pier spacing
must be consistent with home manufacturers instruction and/or state requirements.
Maximumallowable working load for metal strut: 3150 lbs.
1
One Longitudinal Vector System is made up of 2 struts, which can be used separately.
Vector Systems
LSD
LSD LSD
LSD
LSD
Tag or Full Triple
Vertical Anchors
23 Revised: 8/19/08