Example of a Double Section 28' x 72' Home
Vector System
Longitudinal (LSD)
Longitudinal (LSD)
Vector Systems
Vector System
Wind Zone I
WIND ZONE I for Double Section Homes
Using Vector Dynamics Foundation Systems
Soil Classifications: 2, 3, 4A & 4B
Soil Bearing Capacity: 1,000 PSF Minimum
Anchors Required: None(*Marriagewall and sheer wall anchors may be required byhomemanufacturer)
Home Length Vector Systems Anchors Required Longitudinal
Required Per Side Systems
1
(LSD)
0 to 48’ 2 0* 1(2Struts)
49’ to 71’ 3 0* 1(2Struts)
72’ to 84’ 4 0* 1(2Struts)
85’ to 90’ 5 0* 1(2Struts)
NOTES:
*Noanchorsrequiredforpierheightsupto46” for 28’-36’ wide,
38” for 24’ wide. When a pier height at the Vector location is
exceeded, an anchor must be installed outside that location, and
1 longitudinal Vector System added per house.
Vector Systems should be spaced as symmetrical as possible along
the length of the home. Pier spacing must be consistent with home
manufacturers instruction and/or state requirements.
Maximumallowable working load for metal strut: 3150 lbs.
1
One Longitudinal Vector System is made up of 2 struts, which
can be used separately.
15 Revised: 8/19/08