Example of a Single Section 14' x 72' Home
WIND ZONE II for Single Section Homes
Using Vector Dynamics Foundation Systems
Soil Classifications: 2, 3, 4A & 4B
Soil Bearing Capacity: 1,000 PSF Minimum
Anchors Required: 30"with2-4"helixanchors(#59095)with1-1/4"Vertical Ties
Home Length Vector Systems Anchors Required Anchors Required Longitudinal
Required Per Side - 6” Eave over 6” Eave Systems* (LSD)
0 to 48’ 4 4 5 2(4Struts)
49’ to 60’ 5 5 6 2(4Struts)
61’ to 72’ 6 6 7 2(4Struts)
73’ to 84’ 7 7 8 2(4Struts)
85’ to 90’ 8 8 9 2(4Struts)
Vector
Systems
Longitudinal
(LSD)
Longitudinal
(LSD)
Anchors
Vector
Systems
Wind Zone II
NOTES:
Vector Systems should be spaced as symmetrical as possible along
the length of the home. Pier spacing must be consistent with home
manufacturers instruction and/or state requirements.
Maximumallowable working load for metal strut: 3150 lbs.
* One Longitudinal Vector System is made up of 2 struts,
which can be used separately.