Page 10 4/3/2013
Example of a Single Section 14' x 72' H om e
WIND Z
NE I for
ingle
ection Homes
Using V ector Dynamics Foundation System s
Soil Classifications: 2, 3, 4A & 4B
Soil Bearing Capacity: 1,000 PSF Minimum
Anchors Required: 30" with 2-4" helix anchors (#59095) & 12" Stabilizer Plates (#59292)
with 1-1/4" Frame T ie s
Home Length Vector Systems Anchors Required 24+" Piers Longitudinal
Required Per Side Up To 24" Pier Systems* (LSD)
0 to 72' 3 23 1 (2 Struts)
1 (2 Struts)
73' to 90' 4 34
NOTES:
V ector Systems should be spaced as
symmetrical as possible along the length of
the home. Pier spacing must be consistent
with home manufacturers instruction and/or
state requirements.
* One Longitudinal Vector System is made up of 2 struts,
which can be used separatel
.
V ector System s
Longitudinal
(LSD)
Longitudinal
(LSD)
Anchors & Stabilizers
Wind Zone I